Beverage engineering guide

Bottling Line Retrofit and Upgrade Planning

Decide what to retain, modify or replace using measured line performance and a controlled cutover plan.

XGF water filling machine from the Allot Tech catalog, illustrating equipment that requires project-specific line interfaces
Procurement planning resource · Allot Tech

Use this guide to prepare a reviewable request. Confirm the selected article or equipment, test basis and responsibilities in the project scope.

Updated October 17, 2026

Direct answer

Survey the installed line before choosing an upgrade.

A bottling line retrofit starts with the actual installed machines, product and package range, controls and measured output. Record the constraint that the upgrade must remove, then compare retaining, modifying and replacing equipment against the same accepted-pack target. A faster replacement filler is useful only when the remaining preparation, bottle supply, conveyors, closure, labeling and packing stages can support it. Define compatibility, outage work, responsibility and acceptance before ordering.

Build an installed-equipment survey that a supplier can use.

Identify each machine by manufacturer, model, serial number, year and current configuration. Photograph the nameplate and the transfer points; attach the latest available layout, electrical drawings and control backups. Label files as verified, outdated or missing. An old general arrangement drawing is a starting point, not a measured installation record.

Record actual conveyor heights, transfer direction, bottle support and neck handling, cap and label feed, service access and available floor space. List the operating PLC, HMI, drives, network and safety interfaces, with the responsible local engineer reviewing what may be reused. A replacement quote should state which connections it assumes, which adapters it includes and who completes the remaining work.

Check the availability of supported spare parts, software access and service documentation for retained equipment. Name any unresolved ownership or access question in the quotation review so commissioning does not depend on an unavailable program or unidentified component.

Test the bottleneck under the formats you actually sell.

Use a representative running period and count accepted closed and packed containers at a named point. Record the package, recipe, operator arrangement, speed settings, stoppages and blocked or starved periods. Compare the observed restriction with the planned product mix: a small bottle at high speed and a larger bottle with a different label can expose different constraints.

Separate speed loss from rejects, frequent breakdowns and lengthy changeovers. If the filler waits for bottles, investigate blowing or bottle feeding first. If a full discharge conveyor stops filling, review downstream packing and accumulation. Use this evidence to request a targeted remedy, rather than assuming that every low-output line needs a larger filling machine.

Make the shutdown and restart part of the purchase scope.

Agree what can be prepared while the old line runs, what requires isolation and how retained equipment will be protected. Assign dismantling, lifting, electrical work, programming, utility reconnection, format parts and waste handling. Confirm that drawings and parts will be available before the outage starts; calendar duration alone does not describe site readiness.

Define the restart sequence, training and punch-list decisions. Test the complete line with named product and packaging, checking sustained accepted output, transfer stability, closure quality, cleaning boundaries and fault recovery. Where a fallback is technically feasible, agree its trigger and required parts in advance. Keep the acceptance owner and the disposition of unresolved items visible.

Problem case: the replacement is ordered, but nobody owns the transition

Consider an illustrative existing line where a filler is being replaced while the blow molder, labeler and packer stay. The purchase list names the new filler, yet the transfer between the retained conveyor and its inlet is absent. A useful review begins with an interface register: identify the upstream owner, downstream owner, drawing revision, information needed, included work and person accepting the connection. Repeat this for bottles, product, utilities, controls and the agreed safety review. A line drawing with a connecting arrow is not the interface specification.

Ask the parties to distinguish physical readiness from production readiness. A machine can be positioned and connected before formats, control signals, packaging materials, cleaning arrangements and operators are ready for the intended product. Build the restart checklist from the actual retained/new combination. List each open item with a responsible person and the evidence required to close it. If a supplier cannot yet confirm a connection, retain that question as an explicit proposal assumption rather than treating silence as inclusion.

Prepare the shutdown backward from the accepted restart outcome. State what must be measured, manufactured, backed up, delivered or approved before production stops. Identify works that can be completed off-line and those requiring isolation. Have the responsible site team approve the sequence, access and local trade requirements. This guide does not prescribe an electrical or machinery-safety procedure; the people responsible for those activities must define and authorize their methods.

Problem case: a larger machine moves the bottleneck downstream

Suppose the existing constraint is observed during a specific format, but the new proposal is evaluated against a different small bottle. Compare both on the same product, package, run boundary and accepted output. Separate continuous running speed from stop frequency and recovery. Record whether each interruption was caused locally, by missing incoming material or by a full discharge. This identifies what the upgrade has actually changed instead of relying on a single displayed speed.

Request a practical demonstration of the retained downstream path at the target scenario. It may be necessary to change accumulation, control coordination, guides or pack configuration, but the proposal should identify the engineering conclusion rather than assume that one generic conveyor change will solve every case. Include the format range and expected change sequence. If only one format is tested, label that coverage clearly and agree what remains to be demonstrated.

Use the business comparison to show production interruption, installation work, parts, control access, training and support boundaries alongside equipment cost. Keep figures as buyer-entered scenarios unless supported by a written quotation. The decision can then compare targeted modification, stage replacement and broader renewal using one required outcome. It does not need an invented payback percentage or an assumption that every older machine should be discarded.

A reviewable retrofit packet for the next engineering decision

Combine six records: the installed machine register; a measured layout and interface drawings; the product and format list; a representative running record; the proposed retained/new responsibility matrix; and the shutdown/restart acceptance plan. Give each file a revision and an owner. Mark which measurements were verified on site and which came from old documentation. Make photographs identify their location and subject so a detail can be found again.

The acceptance plan should distinguish component checks, integrated dry or basic operation, and the agreed product/package run. For each stage, name the configuration, required materials, measurement and decision maker. Record remaining restrictions if production is released with an authorized exception. Keep that decision separate from final closure so an unresolved integration issue cannot disappear merely because the machine has been delivered.

For the inquiry, explain the current restriction in one sentence, then attach the evidence. For example, an illustrative request might say that the filler repeatedly stops when the packing discharge is full during a named format. This is more useful than asking for the largest available filler. Allot Tech can coordinate the scope discussion with the selected resources; compatibility, execution methods and performance commitments require their project-specific confirmation.

Compare three upgrade routes on the same operating basis.

Illustrative decision framework; suitability depends on the installed condition and confirmed engineering review.

RouteEvidence to requestCommercial boundary to resolve
Modify a retained machineCondition survey, supported conversion design, compatibility and test plan.Included parts, software work, warranty boundary and service support.
Replace the bottleneck stageMeasured constraint and verified rates of retained upstream and downstream stages.Adapters, conveyors, controls, utilities and line-level acceptance.
Extend or replace the lineFuture formats, measured footprint, site capacity and total installed scope.Building works, production interruption, commissioning and disposal.

Prepare the request

Send the inputs needed to review this requirement.

Current line

Machine list, latest layout, photos, controls and available backups.

Operating evidence

Good-pack rate, package mix, stop log, rejects and changeover observations.

Upgrade objective

Named product and format, required accepted output and future changes.

Outage boundary

Permitted shutdown window, local trades, access and restart responsibilities.

Acceptance

Trial conditions, complete-line measurement point and authorized sign-off.

Reference basis

Primary sources for the technical context.

The checklists are Allot Tech procurement guidance. External manufacturer examples do not establish the capabilities of a quoted Allot Tech configuration.

Frequently asked questions

Can a new filler be connected to an old packing line?

Possibly, after transfer geometry, package handling, controls and the packer’s measured capacity are reviewed. Require the proposal to include the necessary interfaces and a complete-line trial.

Does the nameplate rate show the available upgrade capacity?

No. Use a documented run with the actual product and format, and distinguish rated machine output from accepted output across the whole line.

Should every old machine be replaced?

Age alone does not decide. Compare condition, serviceability, safety review, supported controls, operating losses and integration cost before choosing the retained scope.